Heat Shrinkable Terminations Upto 36 kV for Aerial Bunched Cables
zoom view
Ordering Reference
Cable Size (mm2) | For 11/15 kV Kit Code (Indoor) |
---|---|
1 x 16 - 50 | 1XIAB – 15A |
1 x 70 - 120 | 1XIAB – 15B |
1 x 150 - 300 | 1XIAB – 15C |
1 x 400 - 630 | 1XIAB – 15D |
1 x 800 - 1000 | 1XIAB – 15E |
Cable Size (mm2) | For 11/15 kV Kit Code (Outdoor) |
---|---|
1 x 16 - 50 | 1XOAB – 15A |
1 x 70 - 120 | 1XOAB – 15B |
1 x 150 - 300 | 1XOAB – 15C |
1 x 400 - 630 | 1XOAB – 15D |
1 x 800 - 1000 | 1XOAB – 15E |
Cable Size (mm2) | For 22/24 kV Kit Code (Indoor) |
---|---|
1 x 16 - 50 | 1XIAB – 24A |
1 x 70 - 150 | 1XIAB – 24B |
1 x 185 - 300 | 1XIAB – 24C |
1 x 400 - 630 | 1XIAB – 24D |
1 x 800 - 1000 | 1XIAB – 24E |
Cable Size (mm2) | For 22/24 kV Kit Code (Outdoor) |
---|---|
1 x 16 - 50 | 1XOAB – 24A |
1 x 70 - 150 | 1XOAB – 24B |
1 x 185 - 300 | 1XOAB – 24C |
1 x 400 - 630 | 1XOAB – 24D |
1 x 800 - 1000 | 1XOAB – 24E |
Cable Size (mm2) | For 33/36 kV Kit Code (Indoor) |
---|---|
1 x 25 - 50 | 1XIAB – 36A |
1 x 70 - 185 | 1XIAB – 36B |
1 x 240 - 400 | 1XIAB – 36C |
1 x 500 - 800 | 1XIAB – 36D |
1 x 1000 | 1XIAB – 36E |
Cable Size (mm2) | For 33/36 kV Kit Code (Outdoor) |
---|---|
1 x 25 - 50 | 1XOAB – 36A |
1 x 70 - 185 | 1XOAB – 36B |
1 x 240 - 400 | 1XOAB – 36C |
1 x 500 - 800 | 1XOAB – 36D |
1 x 1000 | 1XOAB – 36E |
Technical specifications
Test Sequence | Requirements for 15kV | Requirements for 24kV | Requirements for 36kV |
---|---|---|---|
A/C withstand / 5 Min | 29 kV | 58 kV | 86 kV |
Partial Discharge Test | 11kV<10pc (Max.) | 22kV<10pc (Max.) | 33kV<10pc (Max.) |
Impulses Voltage | 75 kV | 125 kV | 170 kV |
A/C with stand / 15min | 16 kV | 32 kV | 48 kV |
Our Products
-
Joints
- Heat Shrinkable Straight Joint Upto 3.3 kV For XLPE & PILC Cable
- Heat Shrinkable Straight Joint Upto 36 kV For XLPE Cable
- Heat Shrinkable Straight Joint Upto 36 kV For PILC CABLE
- Heat Shrinkable Transition Joints Upto 36 kV (XLPE-PILC)
- Heatshrinkable Straight Through Joints Upto 36 kV for Single Core XLPE Cable
- Heatshrinkable Straight Joint Upto 36 kV For Single Core AB Cable
-
Terminations
- Heat Shrinkable Terminations Upto 3.3 kV For Low Voltage XLPE/PILC Cable
- Heat Shrinkable Terminations Upto 15 Kv Suitable For 1 Core XLPE/EPR Insulated Cable
- Heat Shrinkable Terminations Upto 15 Kv Suitable For 3 Core XLPE/EPR Insulated Cable
- Heat Shrinkable Terminations Upto 15 kV Suitable for 3 Core PILC/MIND Cable
- Heat Shrinkable Terminations Upto 24 kV suitable for 1 Core XLPE/EPR Insulated cables
- Heat Shrinkable Terminations Upto 24 kV suitable for 3 core XLPE/EPR Insulated cables
- Heat Shrinkable Terminations Upto 24 kV For 3 Core PILC/MIND Cable
- Heat Shrinkable Terminations Upto 36 kV for Aerial Bunched Cables
- Heat Shrinkable Terminations Upto 36 Kv Suitable for 1 Core XLPE/EPR Insulated Cables
- Heat Shrinkable Terminations Upto 36 Kv Suitable for 3 Core XLPE/EPR Insulated Cables
- Heat Shrinkable Terminations Upto 36 kV For 3 Core PILC/MIND Cable
-
Accessories
- Heat Shrinkable Cable Breakout
- Heat Shrinkable Rainshed
- Heat Shrinkable Low Voltage Breakout
- Heat Shrinkable Right Angle Boot
- Heat Shrinkable Straight Boot
- Heat Shrinkable Bus Bar Insulation Tape
- Heat Shrinkable Bus Bar Insulation Tube
- Heat Shrinkable Medium wall Tubing
- Heat Shrinkable Semi Conductive Breakout
- Heat shrinkable Anti Tracking Tubing
- Heat Shrinkable Dual Wall Tubing
- Heat Shrinkable Stress Control Tubing
- Heat Shrinkable Wraparound Sleeve