HEATSHRINKABLE TERMINATIONS SUITABLE FOR 11/15 kV, 22/24 kV, 33/36 kV, 1 CORE AERIAL BUNCHED CABLES
Ideal for terminating all 1 core polymeric insulated cables (AB) with various type of semi conducting layers/screen design (copper, tape)
Comes with Aluminium/Copper lugs as per customer's requirement
Use to connect HV/MV cables in utility substations, transformers & switchgear terminals
Ordering Reference
| Cable Size (sq.mm) | For 11/15 kV Kit Code (Indoor) | Number of Rainshed |
| 1 x 16 - 50 | 1XIAB – 15A | 0 Rainshed In 11/15 kV Indoor Terminations |
| 1 x 70 - 120 | 1XIAB – 15B | 0 Rainshed In 11/15 kV Indoor Terminations |
| 1 x 150 - 300 | 1XIAB – 15C | 0 Rainshed In 11/15 kV Indoor Terminations |
| 1 x 400 - 630 | 1XIAB – 15D | 0 Rainshed In 11/15 kV Indoor Terminations |
| 1 x 800 - 1000 | 1XIAB – 15E | 0 Rainshed In 11/15 kV Indoor Terminations |
| Cable Size (mm2) | For 11/15 kV Kit Code (Outdoor) | Number of Rainshed |
| 1 x 16 - 50 | 1XOAB – 15A | 2 Rainshed |
| 1 x 70 - 120 | 1XOAB – 15B | 2 Rainshed |
| 1 x 150 - 300 | 1XOAB – 15C | 2 Rainshed |
| 1 x 400 - 630 | 1XOAB – 15D | 2 Rainshed |
| 1 x 800 - 1000 | 1XOAB – 15E | 2 Rainshed |
| Cable Size (sq.mm) | For 22/24 kV Kit Code (Indoor) | Number of Rainshed |
| 1 x 16 - 50 | 1XIAB – 24A | 1 Rainshed |
| 1 x 70 - 150 | 1XIAB – 24B | 1 Rainshed |
| 1 x 185 - 300 | 1XIAB – 24C | 1 Rainshed |
| 1 x 400 - 630 | 1XIAB – 24D | 1 Rainshed |
| 1 x 800 - 1000 | 1XIAB – 24E | 1 Rainshed |
| Cable Size (sq.mm) | For 22/24 kV Kit Code (Outdoor) | Number of Rainshed |
| 1 x 16 - 50 | 1XOAB – 24A | 3 Rainshed |
| 1 x 70 - 150 | 1XOAB – 24B | 3 Rainshed |
| 1 x 185 - 300 | 1XOAB – 24C | 3 Rainshed |
| 1 x 400 - 630 | 1XOAB – 24D | 3 Rainshed |
| 1 x 800 - 1000 | 1XOAB – 24E | 3 Rainshed |
| Cable Size (sq.mm) | For 33/36 kV Kit Code (Indoor) | Number of Rainshed |
| 1 x 25 - 50 | 1XIAB – 36A | 2 Rainshed |
| 1 x 70 - 185 | 1XIAB – 36B | 2 Rainshed |
| 1 x 240 - 400 | 1XIAB – 36C | 2 Rainshed |
| 1 x 500 - 800 | 1XIAB – 36D | 2 Rainshed |
| 1 x 1000 | 1XIAB – 36E | 2 Rainshed |
| Cable Size (sq.mm) | For 33/36 kV Kit Code (Outdoor) | Number of Rainshed |
| 1 x 25 - 50 | 1XOAB – 36A | 4 Rainshed |
| 1 x 70 - 185 | 1XOAB – 36B | 4 Rainshed |
| 1 x 240 - 400 | 1XOAB – 36C | 4 Rainshed |
| 1 x 500 - 800 | 1XOAB – 36D | 4 Rainshed |
| 1 x 1000 | 1XOAB – 36E | 4 Rainshed |
Technical specifications
| Test Sequence | Requirements for 15kV | Requirements for 24kV | Requirements for 36kV |
| A/C withstand / 5 Min | 29 kV | 58 kV | 86 kV |
| Partial Discharge Test | 11kV<10pc (Max.) | 22kV<10pc (Max.) | 33kV<10pc (Max.) |
| Impulses Voltage | 75 kV | 125 kV | 170 kV |
| A/C with stand / 15min | 16 kV | 32 kV | 48 kV |
CORE Heatshrink Products Company
48, Tyagi Garden, Yamunanagar-135001, Haryana (India)
coreheatshrink@gmail.com
enquiry@coreheatshrink.com
+91-981-3213-489,
+91-972-9423-780
+91-989-6810-913
Please contact us if you need help to understand our products & services
enquiry@coreheatshrink.com©2026 www.coreheatshrink.com. All rights reserved. Design, Develop and Maintained By The Get Enquiry.